1、 The main reason for the detachment of the daylighting board

lighting panelDetachment is not caused by a single factor, but mostly by the combination of multiple problems such as installation, accessories, environment, and maintenance. Common causes can be divided into four categories:

1. The installation process is not standardized. Unreasonable fixed spacing, deviation in drilling position, uneven locking force of nails, and insufficient overlap size can all lead to uneven stress on the daylighting board, gradually loosening and falling off in strong wind and vibration environments.

2. Poor adaptability of fixed accessories. Ordinary self tapping nails and non-standard accessories are used, but there is a lack of waterproof gaskets and pressure strip fixing structures. The weather resistance of the accessories is insufficient, and they are prone to rusting, aging, loosening, and losing their fixing function after long-term exposure to wind and sun.

3. Ignore the allowance for thermal expansion and contraction. The daylighting board will undergo expansion and contraction deformation in alternating high and low temperature environments. If there is insufficient reserved expansion gap during installation, the board will bulge and shrink due to heat, which is prone to tearing, cracking of fixing holes, and overall displacement and detachment.

Fourthly, the post operation and maintenance are not in place. Long term rainwater erosion and sandstorm erosion have led to aging and loosening of fixed points, roof deformation, and steel structure settlement that have not been repaired in a timely manner. Small problems continue to accumulate, causing the entire daylighting panel to fall off.

2、 Core technical measures to prevent the detachment of daylighting panels

1. Standardize installation spacing and balance plate stress

The fixed density of the daylighting board directly determines the overall stability, and excessive spacing can lead to a decrease in the board's ability to withstand wind loads, making it prone to bulging, shaking, and falling off. During the construction process, it is necessary to refer to industry construction standards, arrange fixed points reasonably, and ensure uniform stress distribution in various areas of the board. For locations with high wind loads such as roof slopes, windward surfaces, and eaves, the fixed points can be appropriately increased to enhance the overall wind resistance performance.

At the same time, strict control should be exercised over the overlapping length of the panels, and the horizontal and vertical overlapping dimensions of the roof should comply with engineering specifications to avoid loosening and slipping caused by small overlapping gaps and overlapping misalignment, thereby reducing the risk of detachment from a technical perspective.

2. Select specialized fixed accessories that are compatible to avoid aging and failure of the accessories

The root cause of many lighting panel detachment problems lies in improper selection of accessories. Ordinary iron accessories are prone to rust and corrosion, and long-term use may cause the nail body to loosen or break, making it difficult to firmly fix the plate. To prevent detachment, priority should be given to using specialized fixing accessories that are compatible with the lighting panel, combined with waterproof and weather resistant gaskets, aluminum alloy pressure strips, and specialized fasteners.

Weather resistant accessories can effectively resist outdoor rainwater, ultraviolet radiation, and temperature difference erosion, slow down the aging rate of accessories, and maintain long-term fastening strength. The full coverage fixing method of the pressure strip can disperse the force on a single point, avoid cracking and loosening of the board caused by excessive force on a single nail, and greatly improve the overall stability of the daylighting board fixation.

3. Reserve reasonable expansion and contraction allowance to adapt to thermal expansion and contraction deformation

The mainstream panels such as FRP daylighting panels and fiberglass daylighting panels have normal thermal expansion and contraction characteristics, and the temperature difference changes in all seasons will cause slight expansion and contraction displacement of the panels. If the holes are drilled too tightly and there is no expansion allowance during installation, the board will not be able to expand freely when deformed, which will cause tearing of the fixing holes, deformation and warping of the board, gradually leading to loosening and falling off.

During construction, it is necessary to reserve reasonable expansion and contraction gaps in the fixed hole positions, control the fastening force of the locking nails, and ensure that the fastening is not tight and the fit is not locked. Reserve expansion joints at the splicing positions of the boards to prevent temperature changes from causing mutual compression, bulging, and deformation of the boards, effectively avoiding the risk of detachment caused by deformation.

4. Optimize construction technology and eliminate installation defects

Construction drilling must be kept vertical and flat, and non-standard operations such as oblique drilling, excessive hole enlargement, and hole displacement are prohibited to ensure that fasteners are subjected to vertical and uniform force, and to avoid long-term stress cracking of the hole position. The laying of the board should be kept flat and straight, without distortion, arching, or tension or pulling. The overall board surface should be in contact with the steel structure base surface, reducing the area of hanging and shaking.

For roof vents, eaves, ridges and other locations that are easily disturbed by wind, reinforcement points and sealing treatments can be added to enhance the edge fixing strength and prevent the edges and corners of the board from lifting and gradually falling off as a whole.

5. Perform sealing and waterproof treatment to reduce point corrosion and looseness

Long term infiltration of rainwater into fixed holes can accelerate the corrosion of accessories and the aging of plate holes, leading to the gradual failure of fixed points and a strong hidden cause of detachment. After the installation and construction are completed, all drilling positions, splicing gaps, and pressure strip interfaces need to be sealed and waterproofed, and fully covered with weather resistant sealant for sealing.

The sealing layer can block rainwater and moisture from entering the fixed points, protect fasteners and plate holes from corrosion and aging, maintain the stability of the fixed structure for a long time, and also solve the problem of roof water leakage, achieving both safety and waterproof effect.

3、 Daily inspection and maintenance in the later stage, long-term prevention of detachment problems

Preventing the detachment of daylighting panels is not a one-time construction that can be completed. Long term outdoor use requires regular inspection and maintenance, timely handling of minor hazards, and avoiding the problem from escalating. Daily operation and maintenance can focus on the following points:

1. Seasonal patrol inspection: before and after strong wind, rainstorm and seasonal temperature difference, check the positions of roof plates, fixed accessories and battens, and timely reinforce and repair the loose, warped edges, seal falling off, and corrosion of accessories.

2. Replacement of aging accessories: For accessories and sealing structures that have been in use for a long time, have slight rust, and have aged and cracked adhesive layers, timely replacement and re sealing should be carried out to avoid the failure of accessories and the detachment of boards.

3. Roof load control: It is prohibited to pile up debris or carry out heavy pressure operations on the skylight roof to avoid deformation of the panels, overload of fixed points, and prevent structural loosening caused by human factors.

4. Cleaning up roof debris: Timely clean up fallen leaves, mud, and accumulated water on the roof to avoid long-term accumulation of water and uneven local stress, which may cause deformation and loosening of the panels.

4、 Engineering material selection assisted prevention: improving the stability of board adaptation

The toughness, thickness, and structural process of the board itself can also affect the stability of fixation. During the material selection stage of the project, daylighting panels with standard thickness, stable toughness, and regular craftsmanship can be selected based on the roof span, wind pressure level, and usage environment. The board surface is flat and the fiber distribution is uniform, making it less prone to local brittleness and deformation. It can better adapt to the fixed installation process and reduce the probability of loosening and falling off in the later stage.

Summary

lighting panelThe problem of detachment during use is mostly caused by non-standard installation processes, insufficient fitting of accessories, lack of expansion and contraction allowance, inadequate sealing protection, and negligence in later maintenance. To effectively prevent the detachment of daylighting panels, it is necessary to standardize the construction process, match special weather resistant accessories, reserve expansion gaps, do a good job of sealing and reinforcement, and cooperate with regular inspection and maintenance to ensure the stability of the fixed structure of daylighting panels from multiple aspects. Standardized construction and operation methods can effectively avoid common problems such as looseness, detachment, and water leakage, ensuring the long-term safe and stable use of daylighting roofs.